Guides
A practical glossary of building-security and automation terms
Twenty-five terms boards keep seeing in proposals — OSDP, Wiegand, BACnet, Aliro, PIPEDA and the rest — in plain language, with links to the formal sources.

Boards are often asked to approve a system described in a language the proposal never translates. This glossary covers 25 terms that show up in access, video, networking and building-automation documents. It is a field guide, not a standard. Where a formal specification exists, we point to it.
Access control system (ACS). The combination of readers, door controllers, credentials and software that decides who may open a given door, gate or elevator, and that keeps a record of those events.
Aliro. An open credential and reader-communication standard from the Connectivity Standards Alliance, with a 1.0 specification published in 2026. The buyer-facing promise is interoperability: a credential from one supplier working with a reader from another. Support still has to be checked product by product.
API. An application programming interface: a documented way for one piece of software to request data or actions from another. In a building, an API is often how a work-order system is told that a leak sensor tripped. An API is a contract, not a guarantee that two products share a database.
BACnet. A widely used communications protocol for building automation — heating, cooling, meters and some lighting — maintained as an ASHRAE standard. "BACnet-compatible" means a system can talk on that protocol, not that every point you want is already mapped and licensed.
Credential. The token a person presents to a reader: a fob, a card, a phone pass, a PIN, or a biometric template. The credential is only as useful as the record it points to, and only as safe as the process for issuing and cancelling it.
Controller (door controller). The box, often in a riser or electrical room, that takes a reader’s decision path, drives the lock, and typically stores a local list of who is allowed through that door.
DESFire. A family of high-frequency smart-card technologies, commonly used for more secure physical credentials than older low-frequency proximity fobs. The presence of a DESFire-capable reader does not mean the building is actually issuing DESFire credentials.
Door contact. A sensor that reports whether a door is open or closed. Paired with an access event, it is how a system distinguishes a normal entry from a door held or forced open.
Fail-safe / fail-secure. How a lock behaves if power is lost. A fail-safe lock unlocks (often used on egress doors that must remain a way out). A fail-secure lock stays locked (often used where you cannot afford a door to pop open). Life-safety and security requirements both apply; this is a design choice, not a preference.
Mobile wallet credential. A digital key carried in a phone wallet or vendor app and presented over Bluetooth or NFC. Convenient when it works; incomplete as a sole method unless a backup card and an enrolment plan exist. See our phone-as-key guide.
Modbus. An older, still common protocol for talking to meters, drives and industrial devices. Like BACnet, it is a language, not a finished integration.
NVR. A network video recorder: a local appliance that stores camera streams on a hard drive in the building. Contrast with a VMS that may record in the cloud, on site, or both.
OSDP. The Open Supervised Device Protocol, a Security Industry Association standard for communication between a reader and a controller. It is a modern, supervised alternative to older Wiegand wiring, with support for encryption and for detecting a reader that has been tampered with or swapped.
PIPEDA. The Personal Information Protection and Electronic Documents Act, Canada’s federal private-sector privacy law. Video, access logs and biometrics that identify a person can be personal information. See the OPC’s video surveillance guidelines.
PoE. Power over Ethernet: a network cable that supplies both data and power, often used for cameras, some readers and intercoms. A PoE design is only as reliable as the switch, the backup power behind that switch, and the cable plant.
PACS. Physical access control system, the term many specifications use for an ACS.
Proximity (prox) card. Usually a low-frequency, unencrypted or weakly protected fob or card. Still common in older residential buildings. Easy for residents to use, and often easier than a modern card to copy.
Request-to-exit (REX). A device — a motion sensor, a bar or a button — that tells the system someone is leaving so the door can unlock or the alarm can be shunted without a credential.
RS-485. A wiring standard used for longer, more robust serial runs between controllers and readers, including many OSDP installations.
SLA. A service-level agreement: the written response and restoration times a vendor owes you when the system fails, including after hours. "24/7 support" is not, by itself, an SLA.
Tailgating. Following an authorized person through a door without presenting a credential. A common residential problem, and one that cameras or door contacts can help detect only if they share a timeline with the access event.
VMS. A video management system: the software used to view, search, record and export camera footage. It may be on-site, in the cloud, or hybrid.
Wiegand. An older, still widely installed signalling method between readers and controllers. It is simple and familiar, and it is not a supervised, encrypted reader-to-panel link. Many upgrade conversations start with whether existing Wiegand wiring can be reused or should be replaced with OSDP.
BAS / BMS. Building automation (or management) system: the platform that coordinates HVAC and often lighting, metering and other plant. Integrating a BAS with access or leak detection is a project, not a checkbox; see our guide to integration costs.
Hybrid (cloud and on-site). An architecture in which credentials or recordings can be managed in the cloud while a local controller or recorder keeps the doors and basic functions working during an internet outage. The useful definition is the offline behaviour, not the marketing term.